06.070.0101: Wall Tile – One Coat Method, Wet Area

06.070.0101: Wall Tile - One Coat Method, Wet Area This detail shows tile over concrete masonry (CMU) laid in the one-coat method in a wet area. There is a waterproof membrane over the CMU, metal lath embedded in a bed of mortar, with the tile adhered to a dry-set or latex-modified portland cement mortar bond [...]