Anchored Brick Veneer Base of Wall Detail

With CMU Backing and CMU Foundation Detail: 01.030.0332 This detail illustrates a base of wall condition with a partially grouted and reinforced concrete masonry foundation. Below grade waterproofing and an air/moisture/vapor barrier above grade provide continuous resistance to air and moisture; continuous insulation offers excellent thermal control. The flexible thru-wall flashing is supported across the […]

01.030.0402: Window Sill Detail – Anchored Brick Veneer, CMU Backing

This detail illustrates a masonry window sill condition. The concrete masonry backing is treated with blocking at the perimeter of the opening, which is wrapped with transition material that engages with the air/moisture/vapor barrier in the field of the wall. This provides continuous resistance to air and moisture. Continuous insulation offers excellent thermal control. The […]

01.030.0602: Window Head Detail – Anchored Brick Veneer, CMU Backing

This detail illustrates a masonry window head condition. The concrete masonry backing is treated with blocking at the perimeter of the opening, which is wrapped with transition material that engages with the air/moisture/vapor barrier in the field of the wall. This provides continuous resistance to air and moisture. Continuous insulation offers excellent thermal control. An […]

01.030.0831: Roof-Wall Interface Detail – Anchored Brick Veneer, CMU Backing

Roof wall interface: anchored brick veneer with CMU backing

This detail illustrates a low roof terminating into a higher wall. The tall interior single-wythe CMU wall transitions into an anchored veneer wall above the roof line. The open web steel joists of the roof structure bear on the tall CMU wall via a steel bearing plate on a CMU bond beam. The roof system […]

01.030.0901: Top of Wall Detail – Anchored Brick Veneer, CMU Backing

Outside view of top of wall: anchored brick veneer with CMU backing

This detail illustrates a parapet condition including the roof termination into the masonry wall and the top of wall termination. The open web steel joists of the roof structure bear on the CMU wall via a steel bearing plate on a CMU bond beam. The roof system terminates with the roof counterflashing engaging with the […]