06.080.0243R: Interior Wall Retrofit | Tile over Existing Gypsum Board on Wood or Steel Studs, Cementitious Bond Coat
06.080.0243: Interior wall Retrofit | Tile over Existing Gypsum Board on Wood or Steel Studs, Cementitious Bond Coat This detail illustrates newly installed ceramic, gauged porcelain, stone, or glass tile on exsiting gypsum board backing on existing gypsum board backing on existing steel or wood studs. This is a retrofit application for use on interior [...]03.090.0401: Window Detail – GYP. Sheathing & Wood Studs
03.090.0401: Window Detail - GYP. Sheathing & Wood Studs DOWNLOAD DETAIL06.130.0204: Floor Tile – Over CBU & Cork on Concrete
06.130.0204: Floor Tile - Over CBU & Cork on Concrete This detail shows tile laid on cementitious backer unit (CBU) w/ taped joints on a concrete subfloor, with cork underlayment separating the tile assembly from the concrete for soundproofing. The tile is adhered to the CBU using a dry-set or latex-modified portland cement mortar bond [...]Anchored Brick Veneer Base of Wall Detail
With CMU Backing and CMU Foundation Detail: 01.030.0332 This detail illustrates a base of wall condition with a partially grouted and reinforced concrete masonry foundation. Below grade waterproofing and an air/moisture/vapor barrier above grade provide continuous resistance to air and moisture; continuous insulation offers excellent thermal control. The flexible thru-wall flashing is supported across the […]
02.120.0702: Floor Detail – Hybrid Type IIB
02.120.0702: Floor Detail - Hybrid Type IIB This hybrid masonry and steel floor connection detail makes use of bent reinforcement to tie the the floor to the wall. DOWNLOAD DETAILDynamic 3D Detail Explore the detail and download the Sketchup Model in the 3D Warehouse. Explore Detail07.130.0104: Epoxy Terrazzo – On Concrete W/ Moisture And Anticipated Cracking
07.130.0104: Epoxy Terrazzo - On Concrete W/ Moisture And Anticipated Cracking DOWNLOAD DETAIL07.130.0511: Rustic Terrazzo – System Overview
DOWNLOAD DETAIL04.030.0201: Exterior Stone Attachment Relief Angle & Bent Plate
04.030.0201: Exterior Stone Attachment Relief Angle & Bent Plate DOWNLOAD DETAIL02.010.1311: Control Joint
02.010.1311: Control Joint This detail shows a vertical control joint at intersecting CMU walls. The debonded shear anchor ties the walls together, but also allows the intersecting wall to shrink back from the continuous wall, as the anchor moves along its track. There is horizontal joint reinforcement at 16" o.c. vertically in the wall (not [...]Stone Veneer Walls Laid in Mortar
Hybrid masonry is a structural system that utilizes reinforced masonry infill walls with a framed structure.