03.070.0202: Wall System – Adhered Stone Veneer Over CMU Backup, Sheathing & Z Channels

03.070.0202: Wall System - Adhered Stone Veneer Over CMU Backup, Sheathing & Z Channels This wall system shows adhered stone veneer over concrete masonry backup with sheathing and Z-channels or Z-girts. Rigid insulation resides between the Z-channels. Cement board sheathing is mechanically fastened to the Z-channels, and the thin stone veneer is bonded to the [...]

03.070.0201: Wall System – Adhered Stone Veneer Over CMU Backup, Cont. Insulation

03.070.0201: Wall System - Adhered Stone Veneer Over CMU Backup, Cont. Insulation This wall system shows adhered stone veneer over concrete masonry backup with continuous insulation. The thin stone veneer is bonded to the metal lath with a base coat and bond coat of mortar. The lath is anchored to the backup with mechanical fasteners [...]